
Allen-Bradley 20-HIM-A0
Allen-Bradley repareren bij Cirele is:
• Duidelijke tarieven zonder onverwachte kosten
• Betaling pas na geslaagde reparatie
• Proactieve vervanging van tijdgevoelige onderdelen
• Gedetailleerd test- en reparatierapport wordt verstrekt
• 2 jaar garantie op alle reparaties
• Langdurige ondersteuning tot einde levensduur.
The Allen-Bradley 20-HIM-A0 is a blank/cover plate module belonging to the Human Interface Module (HIM) accessory family for the PowerFlex 700 and PowerFlex 700S series AC drives. Rather than a functional display unit, the 20-HIM-A0 serves as a cover or blank faceplate that occupies the HIM port on the drive when no operator interface is required. It is manufactured by Allen-Bradley, a brand of Rockwell Automation, and is designed to maintain the enclosure integrity of the drive when a full HIM panel is not installed.
The 20-HIM-A0 blank cover is designed to fit the standard HIM port found on PowerFlex 700 series drives, physically sealing the port opening to prevent ingress of dust and contaminants. It does not provide any display, keypad, or communication functionality, as its sole purpose is mechanical coverage. The cover is constructed to match the drive's enclosure rating requirements and snaps securely into the HIM port without tools. It is compatible with the standard HIM port dimensions used across the PowerFlex 700 drive family.
The 20-HIM-A0 is used in industrial installations where the drive is controlled entirely via network communication or remote I/O, and local operator access via a HIM panel is not needed or desired. Typical applications include automated manufacturing lines, conveyor systems, pump and fan control panels, and HVAC installations where the drive is integrated into a PLC-controlled system. Using a blank cover in these scenarios prevents accidental parameter changes at the drive and protects the port from environmental contamination in factory and process environments.
Technical Specifications
| Series/Product Family | PowerFlex 700 / PowerFlex 700S |
|---|---|
| Module Type | Blank Cover / Faceplate |
| HIM Port Compatibility | Standard PowerFlex HIM port |
| Mounting | Snap-in, tool-less installation into HIM port |
| Communication Interface | None (non-functional cover) |
| Display | None |
| Keypad | None |
| Input/Operating Voltage | Not applicable (passive component) |
| Power Consumption | 0 W (no electrical function) |
| Operating Temperature | -20 to +70 degrees C |
| Storage Temperature | -40 to +85 degrees C |
| Certifications | UL, CE (as part of PowerFlex 700 drive system) |
Common Fault Codes
- Fault Code 81
- HIM communication loss. The drive detects that the HIM module or port is not responding as expected.
Verify the HIM or cover plate is fully seated in the HIM port. If using a blank cover, check that the drive parameter for HIM loss action is configured correctly to ignore the absent HIM. - Fault Code 82
- HIM self-test failure. The drive's internal diagnostic detects an issue with the HIM interface circuitry.
Remove and reseat the HIM or blank cover. If fault persists, inspect the HIM port connector on the drive for damage or contamination and replace the HIM module or cover as needed. - Fault Code 70
- Power loss fault. Drive input power has dropped below acceptable levels during operation.
Check incoming supply voltage at the drive input terminals. Verify that all input fuses and circuit breakers are intact and that supply voltage is within the drive's rated input range. - Fault Code 12
- Hardware overcurrent. Drive output current has exceeded the hardware overcurrent trip threshold.
Check motor and output wiring for short circuits or ground faults. Verify motor load conditions and ensure the drive is correctly sized for the application. - Fault Code 13
- Ground fault. A ground fault has been detected on the drive output.
Inspect motor cables and motor windings for insulation breakdown. Disconnect the motor and test insulation resistance. Replace damaged cables or motor as required. - Fault Code 33
- Auto-restart attempts exceeded. The drive has attempted to automatically restart after a fault the maximum configured number of times without success.
Identify and resolve the underlying fault that is causing repeated trips before re-enabling auto-restart. Review fault queue history via a connected HIM or DriveExplorer software. - Fault Code 29
- Analog input loss. The analog reference signal has been lost or fallen below the configured minimum threshold.
Check the analog input wiring and signal source. Verify that the signal level is within the configured input range and that the source device is functioning correctly.
Frequently Asked Questions
What is the purpose of the 20-HIM-A0 and does it provide any control functionality?
The 20-HIM-A0 is a blank cover plate that fills the HIM port on PowerFlex 700 series drives when no operator interface is required. It provides no display, keypad, or communication functionality and is purely a mechanical cover.
Which drives are compatible with the 20-HIM-A0 blank cover?
The 20-HIM-A0 is compatible with Allen-Bradley PowerFlex 700 and PowerFlex 700S series AC drives that feature the standard HIM port. It is not intended for use with PowerFlex 40, 400, or other series that use different HIM port formats.
Can the drive operate normally with the 20-HIM-A0 installed instead of a full HIM panel?
Yes, the drive can operate fully via network communication, remote I/O, or hardwired control inputs with the blank cover installed. The drive parameters should be configured to not generate a fault on HIM loss if no HIM panel is intended to be connected.
Is any wiring or electrical connection required to install the 20-HIM-A0?
No, the 20-HIM-A0 is a passive mechanical cover with no electrical connections. It simply snaps into the HIM port opening on the drive front panel without any wiring.
Can the 20-HIM-A0 be replaced with a functional HIM panel at a later stage?
Yes, the blank cover can be removed and replaced with a functional HIM such as the 20-HIM-C6S or 20-HIM-A6 at any time, as the HIM port remains fully intact beneath the cover.
Troubleshooting
Drive generates a HIM loss fault after installing the 20-HIM-A0 blank cover
Check drive parameter settings for HIM loss action. The drive may be configured to fault when it does not detect a communicating HIM module on the HIM port.
Navigate to the drive's HIM loss parameter (typically found in the communications or fault configuration parameter group) and set the action to 'Ignore' or 'Alarm' rather than 'Fault' to allow operation without a HIM panel.
Blank cover does not seat securely in the HIM port and appears loose
Inspect the retaining clips on the 20-HIM-A0 and the HIM port opening on the drive for damage or deformation. A loose fit may indicate a damaged clip or incorrect installation.
Ensure the cover is aligned correctly with the port and pressed firmly until the retaining clips engage. If the clips are broken, replace the 20-HIM-A0 with a new unit to maintain enclosure integrity.
Drive cannot be accessed for parameter configuration after blank cover is installed
Without a HIM panel, local parameter access is not available. Confirm whether the drive is connected to a network or whether DriveExplorer or Studio 5000 software is available for remote access.
Connect to the drive using Rockwell Automation DriveExplorer or DriveExecutive software via the drive's communication port, or install a compatible HIM panel such as the 20-HIM-C6S temporarily to access and modify parameters.
Visible contamination or debris entering the drive through the HIM port area despite the blank cover being installed
Inspect the 20-HIM-A0 for cracks, warping, or improper seating that may leave gaps around the port opening. Check that the cover is the correct part for the drive model.
Replace the blank cover if damaged or warped. Ensure the correct cover part number is used for the specific drive variant. Verify the cover is fully and evenly seated around the entire perimeter of the HIM port.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Common defects
Common defects on a Allen-Bradley 20-HIM-A0 are:
Power Supply Related Issues
- No power / drive not turning on
- Blown fuses
- Defective rectifier bridge
- Damaged DC bus capacitors
- IGBT / MOSFET module failure
- Overvoltage / undervoltage errors
Control & Electronics Failures
- Faulty control board or PCB damage
- Firmware or memory corruption
- Fieldbus communication errors (Profibus, Modbus, EtherCAT, CANopen)
- Input / output circuit damage
- Gate driver module failure
Motor Control Problems
- Motor not starting or no output
- Unstable speed control
- No torque output
- Trip during acceleration or deceleration
- Encoder feedback errors
Thermal & Cooling Defects
- Overheating due to failed cooling fans
- Defective temperature sensors
- Poor heatsink performance
Mechanical & Environmental Damage
- Burnt or loose connectors
- PCB track damage
- Corrosion or moisture ingress
- Oil, dust or contamination damage
- Cracked solder joints
Error Codes & Drive Trips
- Overcurrent faults (OC)
- Ground fault / earth leakage error
- Short-circuit fault
- Motor or drive overload
- Overvoltage or undervoltage error
- Undervoltage trip when starting or stopping
- Phase loss / imbalance
- Synchronization issues with multiple drives
Other
- Display defect
- Control keys or keypad not working
- Parameters no longer readable or lost
- Brake resistor problems (brake chopper defect)
- Internal relays/contactors defective
- EMI/RFI interference due to defective filters
Related products
-
Lenze Drive ESMD2224TMF
Lenze Drive repair at Cirele is:
• Clear pricing with no surprises
• Payment only after successful repair
• Proactive replacement of time-sensitive components
• Detailed testing and repair report provided
• 2-year warranty on all repairs
• Long-term support until end of life -
Lenze Drive ESMD751X2SFAXXS22
Lenze Drive repair at Cirele is:
• Clear pricing with no surprises
• Payment only after successful repair
• Proactive replacement of time-sensitive components
• Detailed testing and repair report provided
• 2-year warranty on all repairs
• Long-term support until end of life -
Lenze Drive E84ABCHC0000VN0
€ 104,00Lenze Drive repair at Cirele is:
• Clear pricing with no surprises
• Payment only after successful repair
• Proactive replacement of time-sensitive components
• Detailed testing and repair report provided
• 2-year warranty on all repairs
• Long-term support until end of lifeSelect options This product has multiple variants. The options may be chosen on the product page
